Commercial Walk-in Cooler troubleshooting and Repair Service

A commercial walk-in cooler is a vital piece of equipment for any business that needs to store perishable items at a consistent, cold temperature. From supermarkets and restaurants to warehouses and distribution centers, these coolers play a critical role in keeping food, beverages, and other products fresh and safe for consumption. However, even the most well-maintained coolers can experience problems from time to time, which is why it is important to know how to troubleshoot and repair common issues.
Whether you are a business owner, manager, or maintenance technician, this information will help you keep your cooler running smoothly and avoid costly downtime.


Malfunctioning compressor


The compressor is the heart of any refrigeration system, and it is responsible for circulating refrigerant throughout the cooling system. If the compressor is not working properly, the cooler will not be able to maintain the correct temperature. There are several reasons why a compressor might malfunction, including a faulty motor, damaged bearings, or a leak in the refrigerant line.
To troubleshoot a malfunctioning compressor, you can try the following steps:


Check the power supply. Make sure the cooler is plugged in and that the outlet is working properly. You should also check the fuse or circuit breaker to see if it has been tripped.


Reset the compressor. Unplug the cooler and wait a few minutes before plugging it back in. This can sometimes reset the compressor and get it working again.


Check the refrigerant level. If the refrigerant level is too low, the compressor may not be able to function properly. You can check the refrigerant level by using a refrigerant gauge or by calling a professional.


Check for visible signs of damage. Look for any visible signs of damage on the compressor, such as dents, cracks, or leaks. If you find any damage, it is likely that the compressor will need to be replaced.


If these steps do not fix the problem, or if you are unsure of how to proceed, it is always best to call a professional for help. A certified technician will be able to diagnose the problem and recommend the best course of action.


Leak in the refrigerant line


A leak in the refrigerant line can cause the cooler to lose its cooling power and result in higher energy bills. To detect a refrigerant leak, you can look for the following signs:

Ice buildup around the lines


Hissing sound coming from the lines


Visible damage or wear on the lines


If you suspect that there is a leak in the refrigerant line, it is important to call a professional as soon as possible. Handling refrigerant can be dangerous, and it is illegal to do so without proper training and certification. A certified technician will be able to locate and repair the leak, ensuring that your cooler is running efficiently and safely.


Faulty thermostat


The thermostat controls the temperature in the cooler, and if it is not functioning correctly, the cooler may not be able to maintain the desired temperature. To troubleshoot this issue, you can try the following steps:


Check the thermostat settings. Make sure that the thermostat is set to the correct temperature. You can adjust the thermostat and see if the temperature changes.


Check for visible signs of damage. Look for any visible signs of damage on the thermostat, such as cracks or loose wires.


ProfiTech Commercial Refrigeration Service company professionals can troubleshoot and fix a variety of issues with commercial walk-in coolers. Some common issues that can be fixed by repair professionals include:


The cooler isn’t cooling properly: This can be caused by dirty condenser coils, low refrigerant levels, or a faulty thermostat. Repair professionals can clean the condenser coils, refill refrigerant levels, and replace the thermostat to fix this issue.


The door isn’t sealing properly: This can be caused by a damaged door gasket or a misaligned door. Repair professionals can replace the door gasket or adjust the door hinges and latch to fix this issue.
The compressor isn’t running: This can be caused by electrical issues, a faulty compressor, or a refrigerant leak. Repair professionals can check the electrical components, replace the compressor, or repair the refrigerant leak to fix this issue.


The evaporator coils are frozen: This can be caused by low refrigerant levels or a faulty thermostat. Repair professionals can refill refrigerant levels and replace the thermostat to fix this issue.


The fan isn’t working: This can be caused by a faulty fan motor or a clogged fan blade. Repair professionals can replace the fan motor or clean the fan blade to fix this issue.

By working with our repair professionals, you can get these and other issues with your commercial walk-in cooler fixed quickly and efficiently, allowing your business to continue running smoothly.